Terminations

 


Exhaust Cone (EC)

Installed at the top of the grease duct or conduit. It improves the draft and increases the speed of exhaust gases by 50%. Installation of a drain-tee cap (DC) or a drain section (DS) at the base of the grease duct or conduit is required for use of an exhaust cone.
K = 1.25

I.D. A B C
in mm in mm in mm in mm
6 152 4,899 124 8,899 226 17,500 445
8 203 6,532 166 10,532 268 17,500 445
10 254 8,165 207 12,165 309 17,500 445
12 305 9,798 249 13,798 350 17,500 445
14 356 11,431 290 15,431 392 23,500 597
16 406 13,064 332 17,064 433 23,500 597
18 457 14,697 373 18,697 475 23,500 597
20 508 16,330 415 20,330 516 23,500 597
22 559 17,963 456 21,963 558 23,500 597
24 610 19,596 498 23,596 599 23,500 597
26 660 21,229 539 25,229 641 29,500 749
28 711 22,862 581 26,862 682 29,500 749
30 762 24,495 622 28,495 724 29,500 749
32 813 26,128 664 30,128 765 35,500 902
34 864 27,761 705 31,761 807 35,500 902
36 914 29,394 747 33,394 848 35,500 902
38 965 31,027 788 35,027 890 41,500 1054
40 1016 32,660 830 36,660 931 41,500 1054
42 1067 34,293 871 38,293 973 41,500 1054
44 1118 35,926 913 39,926 1014 41,500 1054
46 1168 37,559 954 41,559 1056 41,500 1054
48 1219 39,192 995 43,192 1097 41,500 1054


Closure Section (CS)

Installed at the top of the grease duct or conduit. It protects the grease duct or conduit against water infiltration in the insulation between the inner and outer wall of the grease duct or conduit. Installation of a drain-tee cap (DC) or a drain section (DS) at the base of the grease duct or conduit is required for use of a closure section.