Installation Guide |
||
Pipe and Fitting Joint Assembly, Step by Step |
||
![]() |
![]() |
![]() |
| 1. All components have a male and a female end. The orientation is indicated on the labelling of each section with an arrow. The arrow indicates the direction of the flue. |
2. Before fitting the large and small ends into one another, a sealant (LTS or HTS) is applied on the male end, at the gap between the inner flange and the inner pipe. |
3. Assemble both sections by sliding one section into the other until the flanges meet. A layer of sealant is applied inside the V-Groove of the Assembly band (AB) prior to it’s installation over the joint. |
![]() |
![]() |
![]() |
4. The Assembly Band (AB) is installed and clamped in place with 4 nuts and bolts (supplied). |
5. Insert the insulation strip around the inner joint assembly of insulated models IPPL2 and IPPL2F. |
6. The Finishing Band (FB) is installed by slipping the edges of the band into the outer pipe edges and clamping them with 3 nuts and bolts (supplied). |
7. FOR OUTDOOR INSTALLATION AND BAD WEATHER PROTECTION, AN EXTERIOR SEALANT (ES) IS APPLIED AT THE JOINT BETWEEN THE FINISHING BAND (FB) AND THE OUTER WALL OF THE CHIMNEY. |
||