Inner wall: 316L or 304 2B stainless steel (20 ga - 6'' (152 mm) to 40'' (1016 mm) diameter; 18 ga - 42'' (1067 mm) to 48'' (1219 mm) diameter).
Outer wall: 301, 430, 316L, 304 2B stailess steel or galvalume (24 ga - 6'' (152 mm) diameter; 20 ga - 42'' (1067 mm) to 48'' (1219 mm) diameter).
Continuous laser welding
Full range of accessories including elbows, fittings, guides and supports.
Weights and Clearances
IPPL4F
LINEAR WEIGHT
I.D.
O.D.
AREA
IPPL4F
in
mm
in
mm
in2
mm2
lb/ft
kg/m
6
152
14
356
28
18.2
14.6
21.8
8
203
16
406
50
32.4
17.7
26.3
10
254
18
457
79
50.7
20.7
30.8
12
305
20
508
113
73.0
23.8
35.4
14
356
22
559
154
99.3
26.8
39.9
16
406
24
610
201
129.7
29.9
44.4
18
457
26
660
254
164.2
32.9
49.0
20
508
28
711
314
202.7
35.9
53.5
22
559
30
762
380
245.2
39.0
58.0
24
610
32
813
452
291.9
42.0
62.5
26
660
34
864
531
342.5
45.1
67.1
28
711
36
914
616
397.3
48.1
71.6
30
762
38
965
707
456.0
51.2
76.1
32
813
40
1016
804
518.9
54.2
30.7
34
864
42
1067
908
585.8
57.3
35.2
36
914
44
1118
1018
656.7
60.3
89.7
38
965
46
1168
1134
731.7
63.3
94.3
40
1016
48
1219
1257
810.7
66.3
98.8
42
1067
50
1270
1385
893.8
83.3
124.0
44
1118
52
1321
1521
981.0
87.0
129.4
46
1168
54
1372
1662
1072.2
90.6
134.9
48
1219
56
1422
1810
1167.5
94.3
140.3
MINIMUM CLEARANCE AIR SPACE TO COMBUSTIBLE CONSTRUCTION
MODEL IPPL4F
Inside diameter
Clearance
(1000ºF)
(1000ºF et 1400ºF)
6'' to 12''
1''
14''
1.5''
16'' to 18''
2''
20'' to 22''
3''
24'' to 26''
4''
28'' to 32''
5''
34'' to 36''
6''
38'' to 40''
7''
42'' to 48''
8''
Listings
CHEMINEE LINING.E inc. venting systems models IPPL, IPPL2, IPPL2F and IPPL4F are listed by Underwriters Laboratories, inc. (UL) under file MH26661 and tested in accordance with UL 103 Standard for Factory-Built Chimneys for Residential Type and Building Heating Appliances and the Canadian Standard for 540°C (1000°F) and 760°C (1400°F) industrial Chimneys CAN/ULC-C959. These models are also suitable for use in positive pressure applications up to 60” water column. Listings include the following chimney product categories and diameters..
Building Heating Appliance Chimney Listing (1000°F Chimney Listing) – under this category, models IPPL, IPPL2,IPPL2F and IPPL4F, have been determined suitable for venting flue gases at a temperature not exceeding 540°C (1000°F) under continuous operating conditions, from gas, liquid, oil or solid fuel fired appliances.
Building Heating Appliance Chimneys are suitable for use with Building Heating Appliances and Low Heat Appliances as described in the Chimney Selection Chart of National Fire Protection Association (NFPA) Standard No. 211.
1400°F Chimney Listing – under this category, models IPPL, IPPL2F and IPPL4F, have been determined suitable for venting flue gases at a temperature not exceeding 760°C (1400°F) under continuous operating conditions. As such, they are suitable for use with ovens and furnaces as described in the Chimney Selection Chart of NFPA No. 211, in addition to other applications.